Qualitätspneumatikfilterlufttrockner Filter
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,GUANGZHOU,SHANGHAI |
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,GUANGZHOU,SHANGHAI |
Modell: YD-B058
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Element Serve Life: 6000~8000 Hours
Filtration Performance: From 5 μm To 0.01μm
Maxi. Operate Pressure: 1.6mpa
Operate Temperature: 1.5~80ºc
Flow Rate: 2.8m³/Min
Resistance Corrosion: Inside And Outside
Parts: Dp Indicator, Auto Drain, Sight Glass
Diversion Fin Design On Element Top Cap: Less Pressure Loss
O-Ring Material: Fluororubber
Color: Blue
OEM & ODM Service: Yes
Trademark: Yuka
Transport Package: Brown Inner Box & Cardboard
Specification: Dimension: 120 X 110 X 349mm
Origin: China
HS Code: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Efficiency: F5
Filtration Grade: Medium Filter
Type: Cartridge Filter
Das Arbeitsprinzip des Druckluftfilters:
Schwerkrafteffekt: Wenn die Luftgeschwindigkeit im Filter niedrig ist, werden die meisten Öltröpfchen mit einem Durchmesser von 20-50 ° C durch freie Sturz durch Schwerkraft erfasst, bevor die Filterschicht erreicht ist. Darüber hinaus fällt der Luftstrom weiter und sammelt sich beim Durchfließen des Filters. Je größer die Luftgeschwindigkeit ist, desto niedriger ist ihre Effizienz.
Trägheitsimpaktion: Im Allgemeinen haben suspendierte Partikel mit einem Durchmesser von mehr als 1UM einen großen Impuls. Es stimmt nicht immer mit dem Luftströmungsweg überein, sodass es intial die Faserschicht traf. Je größer die Luftgeschwindigkeit ist, desto größer ist die Kollisionsrate.
Direktes Abfangen: Partikel mit einem Durchmesser von 0,3-1um bewegen sich mit dem Luftstrom, und die meisten von ihnen werden durch die Faserschicht bei 1/2 des Filterelements abgefangen und getrennt. Je kleiner das Teilchen, desto niedriger ist die Abfangrate.
Penetration: Partikel mit einem Durchmesser von weniger als 0,3um. Da die Masse zu klein ist, um die Vielseitigkeit von Flüssigkeiten zu haben, bewegen sie sich in einer unregelmäßigen Brownschen Bewegung. Es ist unvereinbar mit dem Luftströmungsweg, und genau an dieser Bewegung kann es durch eine feinere Filterschicht erfasst werden. Je kleiner die Partikel. Je intensiver die Brownsche Bewegung, desto größer ist die Chance, sie zu fangen.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.