Qualitätspneumatikfilterlufttrockner Filter
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,GUANGZHOU,SHANGHAI |
Ms. YUKA Filtration
Was kann ich für Sie tun?
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,GUANGZHOU,SHANGHAI |
Modell: YD-B058
Material: Aluminiumlegierung
Wohnungsbedienung Lige: 15 Jahre
Element Dienen Leben: 6000 ~ 8000 Stunden
Filtrationsleistung: Von 5 μm bis 0,01 μm
Maxi. Operate Pressure: 1.6mpa
Temperatur Betreiben: 1,5 ~ 80ºC
Fließrate: 2,8 m³/min
Widerstandskorrosion: Innen und außen
Teile: DP -Indikator, Autoabfluss, Sichtglas
Umleitungsflosse Auf Element Top Cap: Weniger Druckverlust
O-Ring Material: Fluororubber
Color: Blue
OEM & ODM -Service: Ja
Warenzeichen: Yuka
Transportpaket: Braune Innenbox & Pappe
Specification: Dimension: 120 X 110 X 349mm
Herkunft: China
HS -Code: 8421399090
Schindel: Ohne Klappbrett
Filter Anzahl: 1
Mittelmaterial: Glasfaser
Effizienz: F5
Filtrationsnote: Mittelfilter
Typ: Kartuschenfilter
Verkaufseinheiten | : | Piece/Pieces |
Pakettyp | : | KARTONSCHACHTEL |
Bildbeispiel | : |
The file is encrypted. Please fill in the following information to continue accessing it
Das Arbeitsprinzip des Druckluftfilters:
Schwerkrafteffekt: Wenn die Luftgeschwindigkeit im Filter niedrig ist, werden die meisten Öltröpfchen mit einem Durchmesser von 20-50 ° C durch freie Sturz durch Schwerkraft erfasst, bevor die Filterschicht erreicht ist. Darüber hinaus fällt der Luftstrom weiter und sammelt sich beim Durchfließen des Filters. Je größer die Luftgeschwindigkeit ist, desto niedriger ist ihre Effizienz.
Trägheitsimpaktion: Im Allgemeinen haben suspendierte Partikel mit einem Durchmesser von mehr als 1UM einen großen Impuls. Es stimmt nicht immer mit dem Luftströmungsweg überein, sodass es intial die Faserschicht traf. Je größer die Luftgeschwindigkeit ist, desto größer ist die Kollisionsrate.
Direktes Abfangen: Partikel mit einem Durchmesser von 0,3-1um bewegen sich mit dem Luftstrom, und die meisten von ihnen werden durch die Faserschicht bei 1/2 des Filterelements abgefangen und getrennt. Je kleiner das Teilchen, desto niedriger ist die Abfangrate.
Penetration: Partikel mit einem Durchmesser von weniger als 0,3um. Da die Masse zu klein ist, um die Vielseitigkeit von Flüssigkeiten zu haben, bewegen sie sich in einer unregelmäßigen Brownschen Bewegung. Es ist unvereinbar mit dem Luftströmungsweg, und genau an dieser Bewegung kann es durch eine feinere Filterschicht erfasst werden. Je kleiner die Partikel. Je intensiver die Brownsche Bewegung, desto größer ist die Chance, sie zu fangen.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.