Customized Air Compressor Coaleszences Filter
$115- /Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Minimum der Bestellmenge: | 10 Piece/Pieces |
Transport: | Ocean,Air,Express |
Hafen: | Shenzhen |
Ms. YUKA Filtration
Was kann ich für Sie tun?
$115- /Piece/Pieces
Zahlungsart: | T/T |
Incoterm: | EXW |
Minimum der Bestellmenge: | 10 Piece/Pieces |
Transport: | Ocean,Air,Express |
Hafen: | Shenzhen |
Modell: YD-B220
Marke: Yuka
Material: Aluminiumlegierung
Wohnungsbedienung Lige: 15 Jahre
Element Serve Life: 6000~8000 Hours For Pf/Ao/Aa/Ax Element Grade
Filtration Performance: 5,1,0.1,0.01 Micron, 0.001mg/M³
Maxi. Operate Pressure: 1.6mpa
Temperatur Betreiben: 1,5 ~ 80ºC
Verbindung: RC2 "
Flow Rate: 12.0m³/Min
Housing Treatment: Anti-Corrosion Inside And Outside
Parts: Manual Ball Valve
O-Ring Material: Fluororubber
Color: Blue
Warenzeichen: Yuka
Transportpaket: Braune Innenbox & Pappe
Specification: Dimension: 120 X 110 X 468 Mm
Herkunft: China
HS -Code: 8421399090
Schindel: Ohne Klappbrett
Filter Anzahl: 1
Mittelmaterial: Glasfaser
Effizienz: F9
Filtrationsnote: Mittelfilter
Typ: Kartuschenfilter
Verkaufseinheiten | : | Piece/Pieces |
Pakettyp | : | KARTONSCHACHTEL |
Bildbeispiel | : |
The file is encrypted. Please fill in the following information to continue accessing it
Wählen Sie Ihren praktischen Luftfilter aus?
Der folgende Schritt hilft Ihnen bei der Auswahl des Situationsfilters für Ihre Bewerbung.
Wenn es einen Punkt gibt, den Sie nicht verstehen, wenden Sie sich bitte an die Anwendungsingenieure von Yuka.
* Bewerten Sie die Anforderungen Ihrer Anwendung. Unterschiedliche Branche erfordern eine unterschiedliche Lösung.
* Welche Art von Filtration wird benötigt? Kohle -Filtermaterial entzieht feste und flüssige Verunreinigungen aus Gasströmen.
Partikelfiltermedien entfernt Feststoff aus Gasströmen. Absorbermedien entfernt Kohlenwasserstoffdämpfe aus Gasströmen.
* Gibt es ein bestimmtes Mikron der Filtrationsleistung, die Sie benötigten?
* Was sind die Arbeitsbedingungen Ihrer Anwendung? Hauptsächlich Kriterien von Bedenken:
Fluss, Arbeitsdruck, Temperatur, Druckverlust, Strukturmaterial (Edelstahl, Aluminiumlegierung, Weichstahl, Kohlenstoffstahl)
* Filterflussrate aus wie viel SCFM? Der Druckabfall sollte weniger als ** bar sein? Um die Kosten zu sparen und die Umgebung zu schützen.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |