4 "Luftfeuchtigkeit Luftfilter für Luftkompressor
$824.321-19 Piece/Pieces
$783.1≥20Piece/Pieces
Zahlungsart: | T/T,L/C |
Incoterm: | FOB,CFR,CIF,EXW |
Transport: | Ocean,Land,Air,Express,Others |
Hafen: | Shenzhen,Guangzhou,Shanghai |
Ms. YUKA Filtration
Was kann ich für Sie tun?
$824.321-19 Piece/Pieces
$783.1≥20Piece/Pieces
Zahlungsart: | T/T,L/C |
Incoterm: | FOB,CFR,CIF,EXW |
Transport: | Ocean,Land,Air,Express,Others |
Hafen: | Shenzhen,Guangzhou,Shanghai |
Modell: YF140
Marke: Yuka
Filtration Grade: Medium Filter
Medium Material: Fiberglass
HS-Code: 8421399090
Color: Red
Origin: China
Clapboard: Without Clapboard
Filter Number: 1
Type: Cartridge Filter
Material: Aluminum Alloy
Filtration Performance: From 5 μm To 0.01μm
Operate Temperature: 1.5~80ºc
Resistance Corrosion: Inside And Outside
Transport Package: Brown Inner Box & Cardboard
Housing Serve Lige: 15 Years
Maxi. Operate Pressure: 1.0mpa
Efficiency: F9
Element Top Cap Design: Colorful To Distinguish
Diversion Fin Design On Element Top Cap: Less Pressure Loss
Element Serve Life: 4000~6000 Hours
Flow Rate: 28.0m³/Min
Connection: Rc4"
Parts: Dp Indicator, Auto Drain Had20b, Sight Glass
Element Material: Sodium Borosilicate Fiber Glass
Entfernen: Oil Vapor, Oil Mist, Dust Particles, Water Mist
Specification: Dimension: 220x 184x 793mm
Verkaufseinheiten | : | Piece/Pieces |
Pakettyp | : | Interne Box und externer Karton |
Bildbeispiel | : |
The file is encrypted. Please fill in the following information to continue accessing it
Feature & Nutzen
① Der Anschlussgrößenbereich von RC1/2 "bis RC 4 " , Durchflussrate von 1,0 m³/min bis 48 m³/min . ② 4000 ~ 6000 Stunden dienen Lebensdauer für Filterelemente, Filtrationsleistung bis zu 99%, Grundlage auf ISO8573.1-2010 Internationaler Standard
③ 15 Jahre Garantie unter Arbeitsbedingung von Temperatur 1,5ºC ~ 80ºC . Maxi. Druck beträgt 1,0 MPa.
④ Niedrigerer Druckverlust, danke für die Top -Kappe des Filterelements mit Umleitungsflossen.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Für die Anwendung im anderen Arbeitsdruck finden Sie die Korrekturfaktoren.
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Ersatz & Ersatzteile
Druckluftlösung
Erfolgreiche Fälle
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.